On 29 December 2025, the Telecommunication Engineering Centre (TEC) issued an update for notification no. 5-5/2024-TC/TEC. The update is pertaining the continuation of exemption various equipment parameters under Mandatory Testing and Certification of Telecom Equipment (MTCTE) certification scheme. Initially, the notification no. 5-5/2024-TC/TEC was issued on 26 June 2025 which allowing manufacturers to submit test reports from laboratories accredited by International Laboratory Accreditation Cooperation (ILAC) for various equipment requirements. The continuation of exemption from various equipment requirements under MTCTE certification scheme has been extended until 30 June 2026.  

In this article, we will discuss all important notes from the current update of notification no. 5-5/2024-TC/TEC and its impact on the TEC MTCTE certification in India.

Key notes of notification no. 5-5/2024-TC/TEC

The update of notification no. 5-5/2024-TC/TEC describes the extension of acceptance test reports from ILAC accredited laboratories to meet the specified test parameters or Essential Requirements (ERs) for various equipment categories. The following table shows the details information of exemption from test parameters (ERs) refer to the latest update on the notification no. 5-5/2024-TC/TEC:

ER ParameterParameters / Interfaces Name (as per ER)Standard Name
(as per ER)
Remark
Mobile Radio Trunking SystemFrequency Band for MRTSNFAP, Annex-C1Exempted for – ETSI EN 300 390, ETSI EN 300 296, ETSI EN 300 341 & ETSI EN 302 561 until 30-06-2026
Conformance to standards for MRTSETSI EN 300 xxx, i.e. 300-086/219/113 /390 /296/341
ETSI EN 301 xxx, i.e. 301-166
ETSI EN 302 xxx. i.e. 302-561 Annex-C3
Max RF Power Output for MRTS Base Stn.As per DoT/WPC license conditions, Annex C2
Repeater for Cellular NetworkGSM Repeater Station Operating FrequencyNFAP. Annex-FExempted until 30-06-2026
GSM Repeater Station Parameters3GPP TS 51.026 and TS 45.005. Annex-F6
WCDMA Repeater Station Parameters3GPP TS 25.143. Annex-F7
WCDMA Repeater Station Operating FrequencyNFAP. Annex-F
LTE Repeater Station Operating FrequencyNFAP. Annex-F
LTE Repeater Station Parameters3GPP TS 36.143. Annex-F8
Precision Timing Protocol Grand Master EquipmentMax Peak Voltage for 10 MHz InterfaceG.703 Annex-IExempted until 30-06-2026
Min Peak Voltage for 10 MHz InterfaceG.703 Annex-I
Profile for frequency synchronisationAnnex-P11
Profile for time and phase synchronisation with full timing supportAnnex-P11
Profile for time and phase synchronisation with partial timing support  Annex-P11
Pulse Shape for 10 MHz InterfaceG.703 Annex-I
Pulse Width for 1 PPS InterfaceG.703 Annex-I
Rise Time for 1 PPS InterfaceG.703 Annex-I
VHF UHF Radio System EquipmentConformance to standards for VHF or UHF Radio SystemsETSI EN 300xxx i.e. 300-113/ 086/219/390/ 296/341/698/783/720 ETSI SN 301-xxx i.e.301- 783/ 925/178
Annex-C3
Exempted for – ETSI EN 300 390, ETSI EN 300 296, ETSI EN 300 341, ETSI EN 300 698, ETSI EN 300 783, ETSI EN 300 720, ETSI EN 301 925, ETSI EN 301 178 until 30-06-2026
Max Transmit Power for VHF or UHF HH Stn.As per DoT/WPC license conditions. AnnexC2
PTP PMP Microwave Fixed Radio SystemsTransmit Power for PMP Radio InterfaceAs per DoT/WPC license conditions. AnnexC2Exempted until 30-06-2026
ADSLxBit Rate for ADSLx Int.Annex-J1Exempted until 30-06-2026
Bit Rate for ADSLx Int.Annex-J1
Insulation Test for ADSL Int.Annex-J1
Line Port impedance for ADSLx Int.Annex-J1
Loop resistance for ADSLxETSI EN 300 001. Annex-J1
PSD for ADSLx Int.Annex-J1
Transmitted Power At ATU- C for ADSLx Int.Annex-J1
VDSLxBit Rate for VDSLx Int.G.993.1 or G993.2. Annex-J1Exempted until 30-06-2026
Line Port impedance for VDSLx Int.G.993.1 or G.993.2 Annex-J1
Loop resistance for VDSLxETSI EN 300 001. Annex-J1
Profiles for VDSLxG.993.1 or G.993.2 Annex- J1
PSD for VDSLx Int.G.993.1 (Cl 6.2). G.993.2 (Cl 7.2) Ann-A B C.Annex-J1
Return Loss for VDSLxG.993.1 or G.993.2 Annex- J1
Transmitted Power At ATU-C for VDSLx Int.G.993.1 or G.993.2 Annex-J1
Optical Fibre (Single Mode)Mechanical Characteristics Proof test for minimum strain level  As per variants of ERExempted until 30-06-2026
Material Properties- Fiber Materials- The substances of  which  the fibres are made  As per variants of ER
Optical Fibre CableLightning TestFOTP-181, ITU-T K-47Exempted until 30-06-2026
DC ResistanceIEEE 1138: 2009
Short Circuit TestIEEE 1138 : 2009/ IEC 60794- 1-2-H1
Lightning Arc TestIEEE 1138 : 2009
Flame Spread- Bunched cableIEC/EN 60332-3-24:2018, Cat C
Smoke Test / Smoke Density TestIEC/EN 61034-2
Acid gas (Toxicity) (Test on toxic gases evolved during combustion of materials from cables)IEC/EN 60754-2
Flame retardantIEC TR62222 IEC 60332-1-2
Electrical Characteristics – Power Feeding WiresIEC 60228, IEC 60502-1, IEC 60227-1, IEC 61156-1 IEC 61196-1-10x BS EN 50525, BS EN 60304
Transfer impedance and Coupling attenuationIEC 61156-1
Requirements for fire performance of Optical/ metallic hybrid cables should meet fire safety regulationsIEC TR 62222
HF Radio SystemConformance to standards for HF Radio SystemsETSI EN 300xxx i.e. 300-433
ETSI EN 301-xxx i.e. 301- 783
ETSI EN 303-xxx. i.e. 303-402 / FCC CFR47 Part 90 Annex-C3
Exempted for ETSI EN 303- 402 / FCC CFR47 Part 90 until 30-06-2026
Frequency for HF equipmentNFAP. Annex-C1
Max Transmit Power for HF Base StnAs per DoT/WPC license conditions. Annex-C2
GSO VSAT/ GSO User TerminalConformance to standards for SatelliteETSI EN 301 443
ETSI EN 301 428
ETSI EN 301 459
ETSI EN 301 447
ETSI EN 302 186
ETSI EN 302 340
ETSI EN 302 977
ETSI EN 303 978
Annex-C3
Exempted until 30-06-2026
NGSO Terminal/ NGSO Integrated GatewayConformance to standards for Satellite-NGSOETSI EN 303 981
ETSI EN 303 980
ETSI EN 303 979
ETSI EN 303 699
Annex-C3
Exempted until 30-06-2026
Satellite Communication EquipmentTransmit Power – Satellite EquipmentAs per DoT/WPC license conditions. Annex-C2  Exempted until 30-06-2026
Cellular Customer Premises Equipment  DHCP client v4/v6RFC 7341 or RFC 8415 Annex.P-12  Exempted until 30-06-2026
All applicable ERsER Interfaces- i). 5G NR- FR1 and FR2 interworking with other Radios ii). 5G NR (FR2)All the parameters corresponding to these interfaces in ERExempted until 30-06-2026
Insulation Resistance for SHDSL IntG.991.2. Annex-J1
LCL for SHDSL InterfaceG.991.2. Annex-J1
PSD for SHDSL IntG.991.2. Annex-J1
Return Loss for SHDSLG.991.2. Annex-J1
Throughput for SHDSL InterfaceG.991.2. Annex-J1
Transmitted Power for SHDSL IntG.991.2. Annex-J1
Frequency Stability-NB-IOT3GPP TS 36.521-1 Clause 6.5.1F
Maximum output power- NB-IOT3GPP TS 36.521-1 Clause 6.2.2F
Operating Frequency-NB- IOT-Device Equp. shall be capable of operating in at least one of the frequency bands as per the National Freq. Allocation planNational Frequency Allocation Plan- 2018 Frequency Allocation Table (IND 16)
Power Control Absolute Power Tolerance-NB-IOT3GPP TS 36.521-1 Clause 6.3.5F.1
Receiver Adjacent Channel Selectivity (ACS) -NB-IOT3GPP TS 36.521-1 Clause 7.5F
Receiver In-band blocking- NB-IOT3GPP TS 36.521-1 Clause 7.6.1F
Receiver Reference Sensitivity level-NB-IOT3GPP TS 36.521-1 Clause 7.3F
Receiver spurious emission-NB-IOT3GPP TS 36.521-1 Clause 7.9F
Spectrum emissions mask- NB-IOT3GPP TS 36.521-1 Clause 6.6.2.1F
Spurious emissions-NB- IOT3GPP TS 36.521-1 Clause 6.6.3F.1-6.6.3F.2

Impact on type approval in India

The extension of exemption from specified test parameters (ERs) on notification no. 5-5/2024-TC/TEC may provide temporary relief for manufacturers and importers, especially when they rely heavily on test reports from international accredited laboratories. However, it is also important to note that the extension of exemption on test parameters (ERs) for specified products on notification no. 5-5/2024-TC/TEC is only valid until 30 June 2026. Manufacturers and importers may need to submit appropriate test reports to meet the test parameters (ERs) after 30 June 2026.

Conclusion

It is important for manufacturers and importers to keep updated with all new requirement of TEC MTECE certification in India, including this update from TEC regarding the extension of exemption period on test parameters (ERs) for various equipment categories.

The implementation of notification no. 5-5/2024-TC/TEC will affect the type approval process for various equipment categories in India. Therefore, Dimulti will closely monitor the update for the requirements of type approval process in India. You can drop an email to info@narmadi.com if further assistance is required regarding India type approval.