Applicable Standards in Indonesia
RFID approval test will be based on national standard: KEPDIRJEN No.214/DIRJEN/2005 for RFID operation in 13.56 MHz, with the key parameters are as follows:
- Radiated Emission Limits
Frequency (MHz) | Field Strength (µV/m) | Measuring Distance (m) |
13.567 – 30.0 | 65 | 10 |
- Error Frequency shall be below 50 KHz
- The Transmission power shall be below 10mW (ERP)
Another kind of RFID approval test will be based on national standard: KEPDIRJEN No.221/DIRJEN/2007 for RFID Operated in 923 – 925 MHz, with the key parameters as follows:
- Radiated Emission Limits
Frequency (MHZ) | Field Strength (µV/m) | Measuring Distance (m) |
923-925 | 500 | 1 |
- Tag utilized shall be passive tags
- Total bandwidth utilization shall be 2 MHz with maximum hopping channel 500 KHz
- The transmission power shall be below 2000mW (ERP)
- Modulation technique: Frequency Hopping Spread Spectrum (FHSS)
- Transmitter antenna shall be embedded with +/- 6 dBi, 5Ω
- Error Frequency: +/-20 ppm from center frequency
- Communication ports:UART, RS-232,RS-485, USB, Serial, Parallel, LAN, WLAN, WAN
- Receiver Sensitivity: max 28dBµV/m or -96dBm, with impedance input 50Ω
Document Requirements
- Power of Attorney to DIMULTI.CV
- Completed Application Forms [ PM.4 and PM.5]
- Technical Data of Device [ General information, Installation Guide, User Manual, Foreign Test Report (optional), etc..]
- More detail please contact us